Semiconductor vacuum systems operate at several distinct pressure levels. Confusing them leads to wrong pump sizing, incorrect leak specs, and misinterpreted gauge readings.

Definitions

  • Base pressure: Lowest stable pressure with pump connected, MFCs closed, after sufficient pumpdown (outgassing/leak limited).
  • Crossover / transition pressure: Pressure at which rough pump hands off to high-vacuum pump.
  • Process pressure: Setpoint during recipe with gas flowing—often orders of magnitude higher than base (mTorr to Torr).

Worked example — Base vs process with site calculators

  1. Base budget: Outgassing Estimator + S_eff → predicted base p.
  2. Process steady state: 150 sccm total, target 12 mTorr → Pumping Speed gives required S ≈ 158 L/s.
  3. Pressure Converter: express 12 mTorr as 1.6 Pa or 16 mbar for vendor docs—avoid unit mix-ups in PLC limits.